Settings In Configuration Files - Siemens SINUMERIK 840D Operator's Manual

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

09.01
1.4

Settings in configuration files

Overview
NETNAMES.INI
© Siemens AG, 2001. All rights reserved
SINUMERIK 840D/810D Configuring the OP 030 Operator Interface (FBO) – 09.01 Edition
Screen Kit: Software Update and Configuration (IK)
The operation of the OP 030 is influenced by the following two files:
– netnames.ini Communications settings for the MPI bus partners
– bd_op030.tea 'Display machine data' (settings for operating modes
via $MM_parameters)
In general, the netnames.ini file does not require manual changes since the
baud rate is set automatically by the OP 030.
The station address can be modified if required.
In the bd_op030.tea file it is possible to, for example, configure the RS-232
interface.
This file contains settings for the MPI/BTSS bus communication partners of
your OP 030. In general, changes are not required in this field.
The line structure of the file is as follows:
<PARAMETER>= <WERT>
[own]
owner =
MMC_1
[conn MMC_1]
conn_1 =
NCU_1
[param network]
mpi
bus =
MPI/OPI bus station addresses:
Each station address must be assigned only once.
Addresses are permissible from 1 through 15.
[param MMC_1]
mmc_address = 10
[param NCU_1]
nck_address =
13
plc_address =
2
If several OP 030s are to be operated at one NCU (NCK+PLC), it is necessary
to change the own station address for the second OP 030 (e.g. from 10 to 11).
1 Software Installation
Must not be changed!
Must not be changed!
Own station address on MPI/OPI bus
NCK address on MPI/OPI bus
PLC address on MPI/OPI bus
IK/1-9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 810d