Program 37 Ring Transfer (Camp-on) Recall Time

Program 37
Ring Transfer (Camp-on) Recall Time
Program Type:
Initialised Default:
(QWHU 3URJ 0RGH
0
6SNU
SELECT = Station Logical Port Number
Enter the port number that needs a Ring Transfer Recall Time assigned.
To add a port range, enter XXX
Port
000
001
002
003
004
005
006
007
008
009
010
011
012
013
Program 37 Overview
If a busy or ringing station does not answer a call sent to it via ring (blind) call transfer (lines
or [DNs]), the station originating the ring (blind) transfer is recalled after an amount of time
determined with this program. This time (011~999 seconds) is set independently for each
originating station port. Initialised data sets all stations for a 032-second recall time. Ring
Transfer must first be enabled for the system with Program 10-1, LED 07 ON.
Strata DK40 Programming Manual Spring 1999
Station
Assigns Ring Transfer Recall Time of 32 seconds to all ports
6
:
+ROG
0
6SNU
*
XXX (low port
*
high port).
Processor
DK40
Hold Time
&
+ROG
0
6SNU
HOLD TIME = Port Number
Enter the Ring Transfer Recall Time (three digits, in seconds)
Enter 000 for no Hold Recall. Enter 011~160 for 11 to 160
seconds.
Port Range
000~027
Port
Hold Time
014
015
016
017
018
019
020
021
022
023
024
025
026
027
System & Station
&
&
+ROG
0
6SNU
&
&
3-81