System & Station

Program 77-2 Overview

This program performs three functions:
Sets number of times door phone rings
Sets fast busy tone if the called door phone does not exist
Configures B-pack on DDCB/HDCB output for door lock control
LED 20: Door Phone Ring Count
The number of times that a door phone will ring digital and electronic telephones is set with
this LED. Light the LED for one ring; turn it OFF for five rings. The default is five rings.
Program 79
LEDs 01, 02, 03, 05, 06, 07, 09, 10 and 11: Door Phone Busy Out
Each door phone controller (DDCB or HDCB) can interface with up to three door phones.
The system treats each controller as a station. Therefore, this is quite different from all other
station arrangements using telephones. Only one door phone can be used at one time. The
system does not automatically know how many door phones are connected to each DDCB or
HDCB, so it must be told.
This program is used to enter that information so that a caller will receive fast busy tone if the
called door phone does not exist. Door phones 1A, 1B, 1C are numbered #151, #152, #153,
respectively, and are connected to the DDCB or HDCB at Port 004. Door phones 2A, 2B, 2C
are numbered #154, #155, #156, respectively, and are connected to the DDCB or HDCB at
port 4 of the first PDKU/PEKU installed in the Expansion Cabinet.
LEDs 04, 08 and 12: Door Lock Assignments
Each B-jack on the DDCB and HDCB output can be configured for door lock control. Door
lock control buttons ( 8QORFN 'RRU 3a6 ) for door locks are assigned to electronic or
digital telephones in Program 39. Door lock activation time is set in
DDCB requires one PDKU circuit, and each HDCB requires one PEKU electronic telephone
circuit. These door locks are not associated with, but are in addition to the door lock control
provided by the PIOU, PIOUS, or PEPU PCB.
3-174
Program 77-2 Door Phone Busy Signal/Door Lock Assignments
DDCB Type
DDCB1
DDCB2
DDCB3
1.
Actual Port numbering depends on the configuration of
the Base KSU (i.e. TBSU (NT) or KSTU installed)
to assign which telephones will be rung by door phones.
DDCB Type
DDCB1
DDCB2
DDCB3
Port 004, second PDKU (Expansion Cabinet)
DK40 Port Number
Port 004, first PDKU
Port 004, second PDKU
DK40 Port Number
004
Port 004, first PDKU (Expansion Cabinet)
Strata DK40 Programming Manual Spring 1999
004
1
1
Program
See
77-1. Each

Hide quick links: