2.13 ADI4 (analog drive interface for 4 axes) (SW 09.01 and higher)
2-114
S
Supply voltage:
An external power supply source 24VDC must be connected to the power
supply of the digital outputs at X6-1, pin 1 (P24EXT2).
The reference ground of the external power supply source must be con-
nected with X6-1, pin 12 (MEXT2).
For further data, see Subsection 2.13.8, page 2-124.
S
Electrical specification of the digital outputs:
Table 2-32
Electrical specification of the digital outputs
Digital outputs
Voltage at high level (V
hi)
Output current I
OUT
Voltage at low level (V
lo)
Leakage current at low level
Signal delay T
and T
PHL
PLH
S
Power supply of the digital outputs
1) typical output voltage:
V
:
CC
Max. output current I
OUT
Max. short-circuit current:
Internal resistance R
:
ON
S
2) The PROFIBUS communication time and the application cycle
time must also be taken into account.
S
Incorrect polarization causes neither high level nor destruction of the outputs.
S
General electrical properties
– Galvanic isolation using optocouplers
– Current limitation to max. 500mA
– Protection from: short-circuit, overtemperature, and loss of ground
– Automatic shutdown on undervoltage.
S
Relay contact Ready signal "Ready"
The relay contact remains open/is opened if one of the follwoing states is
present in the module:
– Initialization after Power On
– Power Failure or NMI
– No cyclic communication to DP master
– PLL error
– Synchronization error
– Overtemperature
The relay contact is closed when the following conditions are satisfied:
– Module status "Ready"
– Cyclic communication with the DP master
min.
typical
V
– 3V
CC
50mA
2)
0.5msec
<R
V
– I
– 0.65V
CC
OUT
ON
Current operating voltage P24EXT2
:
500mA
4A (max. 100msec, V
0.4W
 Siemens AG, 2003. All rights reserved
SINUMERIK 840Di Manual (HBI) – 06.03 Edition
06.03
max.
nominal
1)
V
24V
CC
500mA
0V
400mA
= 24V)