15 SW Installation/Update and Data Backup
15.3 Data backup
15-494
Following menu:
Ghost Connection Mode:
Maximum Backup Images:
Actual Backup Images:
PLEASE SELECT
1
Configure GHOST Parameters
2
Partitions Backup, Mode LOCAL
3
Partitions Restore, Mode LOCAL
4
Delete Image
9
Back to previous Menu
Your Choice [1,2,3,4,9]?
Make sure that the displayed max. number of possible partition backups is
not yet reached.
How to change the max. number, see Subsection 15.3.8 (page 15-495).
To delete partition backups, see Subsection 15.3.9 (page 15-496).
5. Choose the menu item Partitions Backup, Mode LOCAL using key "2".
Following menu:
You must specify the image name (max. 7 characters long):
Image Name:
6. Type the name under which you wish the partition backup to be stored
(max. 7 characters). In the example: IBNZWST
If more than one partition backup is possible, the input option of a descrip-
tion is offered.
You can store a description text along with the image:
description [Local Backup]:
When you select a partition backup to restore it, this description is displayed
together with date and time to identify the partition backup.
To facilitate the identification of the partition backup, a clear description
should be used. In the example: Start-up intermediate version 1.
When you confirm the specifications above, the partition backup will be
started.
After the partition backup has been made, a check can then be carried out
using CRC Check.
LOCAL
<max. number>
<act. number>
 Siemens AG, 2003. All rights reserved
SINUMERIK 840Di Manual (HBI) – 06.03 Edition