16 840Di Specific Data and Functions
16.2 Expanded message frame configuration (SW 2.2 and higher)
16.2.3

Configuring SIMODRIVE drives

Expanded message frame configuration in relation to SIMODRIVE drives:
is illustrated on the basis of an example using SIMODRIVE 611 universal (DP slave 611U). Please
adapt your procedure for the other SIMODRIVE drives.
Recommended
configuration
sequence
Standard
configuration
16-504
S
DP master / SIMATIC STEP 7
No additional requirements
S
SINUMERIK 840Di NC
– SW 2.2 and higher
– Option: "Evaluation of internal drive variables",
Order No.: 6FC5 251-0AB17-0BA0
– NC machine data for activating the data transfer for the additional PDA in
the system variables:
S
MD 36730: DRIVE_SIGNAL_TRACKING[n] (acquisition of additional
drive actual values)
– SIMODRIVE 611 universal/universal E
– SIMODRIVE POSMO CD/CA
– SIMODRIVE POSMO SI.
We recommend proceeding in the following order to configure the components
included in the expanded message frame configuration:
1. Configure the DP master with SIMATIC STEP 7
2. Configure the DP slave 611U with the start-up tool: SimoCom U
3. SINUMERIK 840Di NC with start-up tool: SinuCom NC or the user interface:
HMI Advanced (option).
Before performing the expanded message frame configuration, please define
the following:
– Which standard message frame the drive axis/axes is supposed to oper-
ate with.
– How many additional drive actual values/PDA are to be transferred.
Note
It is advisable to configure each component first with the appropriate standard
message frame and then expand the frame by the additional PDA.