06.03
13.6.5

Display function

Fig. 13-11 Measurement results: Trace function
Soft keys:
X marker ON
Y marker ON
 Siemens AG, 2003. All rights reserved
SINUMERIK 840Di Manual (HBI) – 06.03 Edition
If you press the Display soft key after the set measurement time has expired
and the measurement results have been prepared automatically, you can call
the graphical display function of the measurement results.
When the soft keys X marker ON and Y marker ON are pressed, a vertical or
horizontal line with a circle is displayed on the measurement curve.
The corresponding values, e.g. for damping, frequency, degrees, etc. are dis-
played in the appropriate diagram.
Use the cursor keys to move the markers:
– slowly:
Cursor key
– fast:
Shift key + cursor key
13 Drive Optimization using HMI Advanced