2.7.4
Displaying and editing settable zero offset
All settable offsets, divided into coarse and fine offsets, are displayed in the "Zero Offset -
G54..G599" window.
Rotation, scaling and mirroring are displayed.
Procedure
Note
Activate settable zero offsets
The settable zero offsets must first be selected in the program before they have an impact.
Turning
Operating Manual, 03/2013, 6FC5398-8CP40-3BA1
1.
Select the "Parameter" operating area.
2.
Press the "Zero offset" softkey.
3.
Press the "G54...G599" softkey.
The "Zero Offset - G54..G599" window is opened.
Note
The labeling of the softkeys for the settable zero offsets varies, i.e. the
settable zero offsets configured on the machine are displayed
(examples: G54...G57, G54...G505, G54...G599).
Please observe the machine manufacturer's specifications.
4.
You can edit the values directly in the table.
Setting up the machine
2.7 Zero offsets
87