Siemens SIMATIC S5 Manual page 311

Ip 266 positioning module
Hide thumbs Also See for SIMATIC S5:
Table of Contents

Advertisement

IP 266
START
Enter mode
yes
I 4.5= 1
Override 30%
Target+360.800 mm
Override 60 %
Target -360.600 mm
END
EWA 4NEB 812 6057-02
FB 6 - NAME:MO6
Selecting mode 6
Determining the direction in dependence on
the switch at input 4.5
no
Loading an override factor of 30% and the
integer and decimal digits of the value for
the positive direction of travel:
Loading an override factor of 60% and the
integer and decimal digits of the value for
the negative direction of travel:
MINU
STEP 5 Programming
L
KB 6
T
QB 64
A
I
4.5
JC =MINU
L
KB 30
OVERRIDE 30%
T
QB 67
L
KF +360
T
QW 68
INTEGER DIGITS
L
KF +800
T
QW 70
DECIMAL DIGITS
BEU
L
KB 60
OVERRIDE 60%
T
QB 67
L
KF -360
T
QW 68
INTEGER DIGITS
L
KF +600
T
QW 70
DECIMAL DIGITS
BE