Bcd Output Unit And Controller Communication Unit - Panasonic GP-X Series User Manual

Digital displacement sensor
Hide thumbs Also See for GP-X Series:
Table of Contents

Advertisement

8.1.3 BCD Output Unit and Controller Communication Unit

Designation
Item
Model No.
Model of combination set
Current consumption
(mounting to GP-XC
)
Output
5-digit BCD
polarity indication
VALID
Hold input
Switch
Material
Weight
Accessory
Notes: 1)
The cable for connecting GP-XBCD and controller is the optional cable with connector on one
end for BCD output unit (GP-XBCC3: cable length 3m).
2)
The cable for connecting GP-XCOM with GP-XCOM is the optional link cable for the controller
communication unit (SL-F ).
When a different power supply is used for 2, or more, controllers, be sure
to connect either 0 V lines or +V lines of the controllers each other. Other-
Notice
wise, the transmission by GP-XCOM and the interference prevention func-
tion are not properly operated.
BCD output unit
GP-XBCD
20mA or less
N channel MOS FET open drain
Maximum sink current: 50mA
Applied voltage: 30V DC
(between output and GND)
Residual voltage: 1V (at 50mA sink current)
Non-voltage contact or
NPN open-collector transistor input
Low (0 to 1V): Valid, High (open): Invalid
Enclosure: ABS
30g approx.
Mounting bracket [Stainless steel (SUS304)]: 1 pc. Mounting bracket [Stainless steel (SUS304)]: 1 pc.
Controller communication unit
GP-XC
, GP-XC
-P
5mA or less
Terminator ON/OFF switch
Enclosure: ABS
20g approx.
GP-XCOM
141

Advertisement

Table of Contents
loading

Table of Contents