3.3 Averaging Frequency Setting

Change the averaging frequency to obtain the best relationship between the
response time and variation in detection.
If high-speed judgment is necessary, set a smaller averaging frequency.
For momentary changes or fine judgment, set a larger averaging frequency
to suppress any variation in detection.
POINT
■ Relationship Between Averaging Frequency and Response Time
Averaging
Response time (ms)
frequency
1
2
4
8
16
32
64
:Factory shipment setting
Setting example
Change the averaging frequency to "1,024" times.
<Detection state>
Averaging frequency
setting mode
Averaging
frequency
0.075
128
0.100
256
0.150
512
0.250
1,024
0.450
2,048
0.850
4,096
1.650
8,192
16,384
Press
to select "AVE".
Press the
key to turn off the indicator to return to the detection mode.
Response time (ms)
3.250
6.450
12.850
25.650
51.250
102.450
204.850
409.650
The
key indicator lights up.
Press
to select "1,024".
51