1.6 Mounting Method

The procedure for mounting the GP-X series to a panel is described.

1.6.1 Mounting the Controller

1. Cut a mounting hole in the pan-
el.
45
+0.6
0
45
+0.6
0
Without an optional unit (unit: mm)
45
+0.6
0
45
+0.6
0
A
Min. 90
A
Note: The panel thickness must be from 1 to 5mm.
With optional units (unit: mm)
90 or more
100 or more
Note: The panel thickness must be from 1 to 2.5mm.
To mount the optional controller communication unit (GP-XCOM) or BCD
output unit (GP-XBCD) to the controller, mount the controller on the panel
Notice
first.
16
(unit: mm)
1 to 5
To mount the communication
unit or BCD output unit, the
thickness must be from 1 to
2.5mm.
For continuous side mounting
A = (48 n
2.5)
n : The Number of the units to
be mounted
2. Insert the controller into the
mounting hole from the rear.
3. Fit the mounting frame from the rear.
4. Tighten the screw of the mounting frame.
To
mount
the
c o m m u n i c a t i o n
unit or BCD output
unit, observe the
orientation shown
in the figure.