3.2.3 Using the Actual Detection Value to Set (Teaching)

Setting example
Change the upper limit value from "1.5000" to "1.7000".
<Detected state>
Upper limit value
setting mode
・Use as the upper threshold (H-thr) value is zero or greater.
・Enter settings so that the following equation stands true:
Upper limit value (H-thr) - hysteresis width (o-hys) > Lower limit value
(L-thr) + hysteresis width (o-hys).
POINT
If the conditions are not satisfied, an error message is displayed.
Press the
50
Press
to select "H-thr".
Press and hold
seconds to teach.
key to remove the error indication. Enter the correct value.
for more than two
The blinking value indicates
that the distance between
the
sensor
detected object is "1.2350".
Change
the
(blinking value) between
Set
the sensor head and the
detected object to "1.7000"
then press the
set.
head
and
distance
key to

Advertisement