Cyclic Trigger Setting - Panasonic GP-X Series User Manual

Digital displacement sensor
Hide thumbs Also See for GP-X Series:
Table of Contents

Advertisement

・Enter the settings so that the trigger level and the sum of the trigger level
and trigger hysteresis become within 110% and 120% of the maximum
detection distance, respectively.
Example: 2mm type sensor head
Trigger level: 2.2mm
Trigger level + trigger hysteresis: 0 to 2.4mm
POINT
・ The setting range of the trigger delay and sampling time is 0 to 99.9999 sec.
・If an interference prevention setting is given, the delay and sampling time
become longer. Check during actual operation.

3.5.3 Cyclic Trigger Setting

When the cyclic trigger is set, operation menus proceed according to the fol-
lowing procedure.
Select the cyclic trigger.
Setting example
Change the trigger period from 1.0 sec. to 3.5 sec.
<Cyclic trigger>
The setting range is between 0.0001 and 99.9999 sec.
If an interference prevention setting is given, the cyclic trigger period be-
comes longer. Check during actual operation.
POINT
Through zero setting (or cancellation), trigger direction change or scale
change, the trigger level and hysteresis are automatically adjusted to op-
timum values. If the trigger level and trigger hysteresis exceed the above
range, they are automatically contained in the maximum setting range.
Be careful if the trigger level and trigger hysteresis are nearly set at the up-
per limit of the detection range.
Set the trigger period.
Press
Press
Set
to move to another digit.
or
to change the number.
65

Advertisement

Table of Contents
loading