KCH-14
POWER
GRP
TX BUSY
VOL
CH
KCH-15
POWER
CALL
MON
SCAN
GRP
TX
BUSY
VOL
CH
Fig. 1-3
Fig. 1-4 Keytop insertion
Fig. 1-5 Keytop removal
INSTALLATION
PF1
PF2
PF3
PF4
PF5
PF6
PF7
MON
SP
OPT
A
B
C
OST
SCN
PF8
PF9
PF1
PF2
PF3
PF4
PF5
TK-5810
2. Remote kit (KRK-5: Option)
The KRK-5 remote kit is used to remotely operate the
transceiver. The KRK-5 is connected to the KCH-14 or KCH-
15 with an optional KCT-22M (8 feet), KCT-22M2 (17 feet),
or KCT-22M3 (25 feet) control cable.
2-1. Installing the KRK-5 main panel onto the
transceiver
1. Remove the upper case and lower case of the transceiv-
er.
2. Insert the lead wire with connector (W700) of the control
unit (X53-440) into the connector (CN4) of the KRK-5.
3. Install the KRK-5 main panel on the transceiver using
four screws q.
Note:
Take care that the lead wire with connector (W700) is not
caught when fi tting the KRK-5 main panel on the trans-
ceiver.
4. Affixing the sheet (G11-4379-04) for the waterproof
(Fig.2-1-2).
(1) Remove the covering paper of the sheet w.
(2) Affi x the sheet while taking note of the position of the
three parts as shown in Fig.2-1-2 e.
Firmly affi x the sheet to the chassis by pushing the
double-coated tape with your fi ngers.
(3) Repeat step (2) to affi x the sheet to the other side of
chassis.
Note:
The sheet cannot be reused. Affix a new sheet when
you removed the sheet.
5. Reassemble the upper case and lower case of the trans-
ceiver. (Refer to page 18)
Note:
Take care that the sheet (G11-4379-04) is not peeled off
when installing the upper/lower case.
Transceiver
W700
Packing
CN4
KRK-5 main panel
Fig. 2-1-1
BG
/5810H
BG
(
)
(
)
13