TK-5810
BG
(
Item
Panel tuning mode
2. AF level
[Panel test mode]
setting
1) CH-Sig: 1-1
Filter: W
SSG output
: –47dBm (1mV)
(MOD: 1kHz/±3kHz)
3. Sensitivity
[Panel test mode]
check
1) CH-Sig: 1-1
(Wide)
Filter: W
SSG output
: –117dBm (0.32µV)
(MOD: 1kHz/±3kHz)
2) CH-Sig: 2-1
3) CH-Sig: 3-1
(Narrow)
1) CH-Sig: 1-1
Filter: N
SSG output
: –117dBm (0.32µV)
(MOD: 1kHz/±1.5kHz)
2) CH-Sig: 2-1
3) CH-Sig: 3-1
4. Squelch
1) Adj item: [SQOW]
Open
Adjust: [✳✳✳]
(Wide)
2) Adj item:
[L]→[C]→[H]
SSG output: 12dB
SINAD level for
analog Wide –3.0dB
(MOD: 1kHz/±3kHz)
After input signal
from SSG, press
[PF5] key to store
the adjustment
value.
(Narrow)
1) Adj item: [SQON]
Adjust: [✳✳✳]
2) Adj item:
[L]→[C]→[H]
SSG output: 12dB
SINAD level for ana-
log Narrow –3.0dB
(MOD: 1kHz/±1.5kHz)
After input signal
from SSG, press
[PF5] key to store
the adjustment
value.
70
/5810H
BG
)
(
)
ADJUSTMENT
Condition
PC test mode
equipment
[PC test mode]
SSG
1) Channel: 1
Signaling: 1
DVM
Bandwidth
AF VTVM
: 5kHz/25.0kHz
Dummy
SSG output
load (4Ω)
: –47dBm (1mV)
(MOD: 1kHz/±3kHz)
[PC test mode]
SSG
1) Channel: 1
Signaling: 1
AF VTVM
Bandwidth
Oscillo-
: 5.0kHz/25.0kHz
scope
SSG output
: –117dBm (0.32µV)
(MOD: 1kHz/±3kHz)
2) Channel: 2
3) Channel: 3
1) Channel: 1
Signaling: 1
Bandwidth
: 2.5kHz/12.5kHz
SSG output
: –117dBm (0.32µV)
(MOD: 1kHz/±1.5kHz)
2) Channel: 2
3) Channel: 3
1) Adj item: [Squelch
Open (Wide)]
2) Adj item: [Low]→
[Center]→[High]
SSG output: 12dB
SINAD level for
analog Wide –3.0dB
(MOD: 1kHz/±3kHz)
After input signal
from SSG, press
[Apply] button to
store the adjust-
ment value.
1) Adj item: [Squelch
Open (Narrow)]
2) Adj item: [Low]→
[Center]→[High]
SSG output: 12dB
SINAD level for ana-
log Narrow –3.0dB
(MOD: 1kHz/±1.5kHz)
After input signal
from SSG, press
[Apply] button to
store the adjust-
ment value.
Measurement
Test-
Unit Terminal Unit
Rear
ANT
panel
Ext.SP
connector
ANT
Ext.SP
connector
Adjustment
Specifi cations /
Parts
Method
Volume
Turn the Volume
2.0V±0.3V
knob
knob to obtain 2.0V
AF output.
(2W @4Ω load)
Check
12dB SINAD or
more
[Panel
[Panel tuning mode]
tuning
After input signal
mode]
from SSG, press
[PF5]
[PF5] key to store
the adjustment
[PC test
value.
mode]
[Apply]
[PC test mode]
After input signal
from SSG, press
[Apply] key to store
the adjustment
value.
Remarks