Item
Panel tuning mode
(Narrow)
1) Adj item: [HRSIN]
Adjust: [✳✳✳]
2) Adj item:
[L]→[C]→[H]
SSG output
: –70dBm (70.7µV)
(MOD: OFF)
After input signal
from SSG, press
[PF5] key to store
the adjustment
value.
(P25)
1) Adj item: [HRSIA]
Adjust: [✳✳✳]
2) Adj item:
[L]→[C]→[H]
SSG output
: –70dBm (70.7µV)
(MOD: OFF)
After input signal
from SSG, press
[PF5] key to store
the adjustment
value.
Radio Check Section
Item
Panel tuning mode
1. Frequency
[Panel test mode]
check
1) CH-Sig: 1-3
PTT: ON
2. High
[Panel test mode]
power
1) CH-Sig: 1-1
check
2) CH-Sig: 2-1
TK-5810(BG)
3) CH-Sig: 3-1
PTT: ON
TK-5810H(BG)
3. Low power
[Panel test mode]
check
1) CH-Sig: 1-1
TK-5810(BG)
2) CH-Sig: 2-1
3) CH-Sig: 3-1
TK-5810H(BG)
PTT: ON
ADJUSTMENT
Condition
PC test mode
equipment
1) Adj item: [RSSI
SSG
(–70dBm) (Narrow)]
2) Adj item: [Low]→
AF VTVM
[Center]→[High]
Oscillo-
SSG output
scope
: –70dBm (70.7µV)
(MOD: OFF)
After input signal
from SSG, press
[Apply] button to
store the adjust-
ment value.
1) Adj item: [RSSI
(–70dBm) (P25)]
2) Adj item: [Low]→
[Center]→[High]
SSG output
: –70dBm (70.7µV)
(MOD: OFF)
After input signal
from SSG, press
[Apply] button to
store the adjust-
ment value.
Condition
PC test mode
equipment
[PC test mode]
f. counter Rear
1) Channel: 3
Signaling: 1
PTT : Press [Trans-
mit] button.
[PC test mode]
Power
1) Channel: 1
meter
2) Channel: 2
Ammeter
3) Channel: 3
PTT: Press [Trans-
mit] button.
[PC test mode]
1) Channel: 1
2) Channel: 2
3) Channel: 3
PTT: Press [Trans-
mit] button.
TK-5810
Measurement
Test-
Unit Terminal Unit
Rear
ANT
panel
Ext.SP
connector
Measurement
Test-
Unit Terminal Unit
ANT
panel
BG
/5810H
(
)
Adjustment
Specifi cations /
Parts
Method
[Panel
[Panel tuning mode]
tuning
After input signal
mode]
from SSG, press
[PF5]
[PF5] key to store
the adjustment
[PC test
value.
mode]
[Apply]
[PC test mode]
After input signal
from SSG, press
[Apply] key to store
the adjustment
value.
Adjustment
Specifi cations /
Parts
Method
Check
K
±0.40ppm
-207Hz~+207Hz
@519.90MHz
K2
±0.40ppm
-187Hz~+187Hz
@469.90MHz
38.3~51.8W
14.0 A or less
K
Channel: 1/2
85.0~115.0W
Channel: 3
51.0~69.0W
K2
85.0~115.0W
4.0~6.0W
45.0~55.0W
BG
(
)
Remarks
Remarks
73