Item
Panel tuning mode
(Narrow)
1) Adj item: [MSKN]
Adjust: [✳✳✳]
Deviation meter
LPF: 15kHz
HPF: OFF
Detector: ±PEAK/2
PTT: ON
Press [PF5] key to
store the adjust-
ment value.
*4: Refer to the "Necessary Deviation adjustment item for each signaling and mode" table on page 69.
Balance adjustment is common with the adjustment of all signaling deviation.
■ Necessary Deviation adjustment item for each signaling and mode
Mode
Signaling
1. Balance adjust
Audio
2. Analog Deviation adjust (Wide)
1. Balance adjust
QT
2. Analog Deviation adjust (Wide)
3. QT Deviation adjust (Wide)
1. Balance adjust
DQT
2. Analog Deviation adjust (Wide)
3. DQT Deviation adjust (Wide)
Analog
1. Balance adjust
DTMF
2. Analog Deviation adjust (Wide)
3. DTMF Deviation adjust (Wide)
1. Balance adjust
Single Tone
2. Analog Deviation adjust (Wide)
3. Single Tone Deviation adjust (Wide)
1. Balance adjust
MSK
2. Analog Deviation adjust (Wide)
3. MSK Deviation adjust (Wide)
P25
Receiver Section
Item
Panel tuning mode
1. RX Front-
1) Adj item: [FEND]
end write
Adjust: [✳✳✳]
2) Adj item: [L]→[LC]
→[C]→[CH]→[H]
Adjust: [✳✳✳]
Press [PF5] key to
store the adjust-
ment value.
ADJUSTMENT
Condition
PC test mode
equipment
1) Adj item: [MSK
Deviation
Deviation (Narrow)]
meter
Deviation meter
Oscilloscope
LPF: 15kHz
HPF: OFF
Detector: ±PEAK/2
PTT: Press [Trans-
mit] button.
Press [OK] button
to store the adjust-
ment value.
Wide
Condition
PC test mode
equipment
1) Adj item: [Receive
Front-end]
2) Adj item: [Low]→
[Low']→[Center]→
[High']→[High]
Press [OK] button
to store the adjust-
ment value.
TK-5810
Measurement
Test-
Unit Terminal Unit
Rear
ANT
panel
Necessary adjustment and order
1. Balance adjust
2. Analog Deviation adjust (Narrow)
1. Balance adjust
2. Analog Deviation adjust (Narrow)
3. QT Deviation adjust (Narrow)
1. Balance adjust
2. Analog Deviation adjust (Narrow)
3. DQT Deviation adjust (Narrow)
1. Balance adjust
2. Analog Deviation adjust (Narrow)
3. DTMF Deviation adjust (Narrow)
1. Balance adjust
2. Analog Deviation adjust (Narrow)
3. Single Tone Deviation adjust (Narrow)
1. Balance adjust
2. Analog Deviation adjust (Narrow)
3. MSK Deviation adjust (Narrow)
1. Balance adjust
2. P25 Deviation adjust
Measurement
Test-
Unit Terminal Unit
BG
/5810H
(
)
Adjustment
Specifi cations /
Parts
Method
[Panel
Write the value as
±50Hz
tuning
followings.
mode]
134 (Reference
[PF3]
value)
[PF4]
1.50kHz
[PC test
mode]
[ ],[ ]
Narrow
Adjustment
Specifi cations /
Parts
Method
Enter the following
adjustment values
to the transceiver.
K
[L (Low)]: 210
[LC (Low')]: 175
[C (Center): 130
[CH (High')]: 95
[H (High)]: 65
K2
[L (Low)]: 200
[LC (Low')]: 155
[C (Center): 115
[CH (High')]: 80
[H (High)]: 50
BG
(
)
Remarks
Remarks