Kenwood TK-5810 Service Manual page 68

Uhf p25 transceiver
Hide thumbs Also See for TK-5810:
Table of Contents

Advertisement

TK-5810
BG
(
Item
Panel tuning mode
11. DTMF
1) Adj item: [DTMW]
Deviation
Adjust: [✳✳✳]
write *4
Deviation meter
(Wide)
LPF: 15kHz
HPF: OFF
Detector: ±PEAK/2
PTT: ON
Press [PF5] key to
store the adjust-
ment value.
(Narrow)
1) Adj item: [DTMN]
Adjust: [✳✳✳]
Deviation meter
LPF: 15kHz
HPF: OFF
Detector: ±PEAK/2
PTT: ON
Press [PF5] key to
store the adjust-
ment value.
12. Single
1) Adj item: [2TNW]
Tone
Adjust: [✳✳✳]
Deviation
Deviation meter
write *4
LPF: 15kHz
(Wide)
HPF: OFF
Detector: ±PEAK/2
PTT: ON
Press [PF5] key to
store the adjust-
ment value.
(Narrow)
1) Adj item: [2TNN]
Adjust: [✳✳✳]
Deviation meter
LPF: 15kHz
HPF: OFF
Detector: ±PEAK/2
PTT: ON
Press [PF5] key to
store the adjust-
ment value.
13. MSK
1) Adj item: [MSKW]
Deviation
Adjust: [✳✳✳]
write *4
Deviation meter
(Wide)
LPF: 15kHz
HPF: OFF
Detector: ±PEAK/2
PTT: ON
Press [PF5] key to
store the adjust-
ment value.
*4: Refer to the "Necessary Deviation adjustment item for each signaling and mode" table on page 69.
Balance adjustment is common with the adjustment of all signaling deviation.
68
/5810H
BG
)
(
)
ADJUSTMENT
Condition
PC test mode
equipment
1) Adj item: [DTMF
Deviation
Deviation (Wide)]
meter
Deviation meter
Oscilloscope
LPF: 15kHz
HPF: OFF
Detector: ±PEAK/2
PTT: Press [Trans-
mit] button.
Press [OK] button
to store the adjust-
ment value.
1) Adj item: [DTMF
Deviation (Narrow)]
Deviation meter
LPF: 15kHz
HPF: OFF
Detector: ±PEAK/2
PTT: Press [Trans-
mit] button.
Press [OK] button
to store the adjust-
ment value.
1) Adj item: [Single
Tone Deviation
(Wide)]
Deviation meter
LPF: 15kHz
HPF: OFF
Detector: ±PEAK/2
PTT: Press [Trans-
mit] button.
Press [OK] button
to store the adjust-
ment value.
1) Adj item: [Single
Tone Deviation
(Narrow)]
Deviation meter
LPF: 15kHz
HPF: OFF
Detector: ±PEAK/2
PTT: Press [Trans-
mit] button.
Press [OK] button
to store the adjust-
ment value.
1) Adj item: [MSK
Deviation (Wide)]
Deviation meter
LPF: 15kHz
HPF: OFF
Detector: ±PEAK/2
PTT: Press [Trans-
mit] button.
Press [OK] button
to store the adjust-
ment value.
Measurement
Test-
Unit Terminal Unit
Rear
ANT
panel
Adjustment
Specifi cations /
Parts
Method
[Panel
Write the value as
±100Hz
tuning
followings.
mode]
170 (Reference
[PF3]
value)
[PF4]
3.00kHz
[PC test
mode]
[ ],[ ]
Write the value as
±50Hz
followings.
171 (Reference
value)
1.50kHz
Write the value as
±100Hz
followings.
133 (Reference
value)
3.00kHz
Write the value as
±50Hz
followings.
133 (Reference
value)
1.50kHz
Write the value as
±100Hz
followings.
132 (Reference
value)
3.00kHz
Remarks