Kenwood TK-5810 Service Manual page 66

Uhf p25 transceiver
Hide thumbs Also See for TK-5810:
Table of Contents

Advertisement

TK-5810
BG
(
Item
Panel tuning mode
5. Balance
1) Adj item: [BAL]
adjust *2
Adjust: [✳✳✳]
Deviation meter
LPF: 15kHz
HPF: OFF
2) Adj item: [L]→[LC]
→[C]→[CH]→[H]
Adjust: [✳✳✳]
PTT: ON
Press [PF5] key to
store the adjust-
ment value.
6. Maximum
1) Adj item: [FMWD]
Deviation
Adjust: [✳✳✳]
adjust *2
Deviation meter
(Wide)
LPF: 15kHz
HPF: OFF
Detector: ±PEAK/2
2) Adj item: [L]→[LC]
→[C]→[CH]→[H]
Adjust: [✳✳✳]
PTT: ON
Press [PF5] key to
store the adjust-
ment value.
(Narrow)
1) Adj item: [FMND]
Adjust: [✳✳✳]
2) Adj item: [L]→[LC]
→[C]→[CH]→[H]
Adjust: [✳✳✳]
PTT: ON
Press [PF5] key to
store the adjust-
ment value.
7. P25 high
1) Adj item: [HDVA]
deviation
Adjust: [✳✳✳]
*2
Deviation meter
LPF: 3kHz
HPF: OFF
Detector: ±PEAK/2
2) Adj item: [L]→[LC]
→[C]→[CH]→[H]
Adjust: [✳✳✳]
PTT: ON
Press [PF5] key to
store the adjust-
ment value.
*2: Refer to the "Necessary Deviation adjustment item for each signaling and mode" table on page 69.
Balance adjustment is common with the adjustment of all signaling deviation.
66
/5810H
BG
)
(
)
ADJUSTMENT
Condition
PC test mode
equipment
1) Adj item: [Balance]
Deviation
Deviation meter
meter
LPF : 15kHz
Oscilloscope
HPF : OFF
2) Adj item: [Low]→
[Low']→[Center]→
[High']→[High]
PTT: Press [Trans-
mit] button.
Press [OK] button
to store the adjust-
ment value.
1) Adj item: [Max
Deviation (Wide)]
Deviation meter
LPF : 15kHz
HPF : OFF
Detector: ±PEAK/2
2) Adj item: [Low]→
[Low']→[Center]→
[High']→[High]
PTT: Press [Trans-
mit] button.
Press [OK] button
to store the adjust-
ment value.
1) Adj item: [Max
Deviation (Narrow)]
Deviation meter
LPF : 15kHz
HPF : OFF
Detector: ±PEAK/2
2) Adj item: [Low]→
[Low']→[Center]→
[High']→[High]
PTT: Press [Trans-
mit] button.
Press [OK] button
to store the adjust-
ment value.
1) Adj item: [P25 High
Deviation]
Deviation meter
LPF : 3kHz
HPF : OFF
Detector: ±PEAK/2
2) Adj item: [Low]→
[Low']→[Center]→
[High']→[High]
PTT: Press [Trans-
mit] button.
Press [OK] button
to store the adjust-
ment value.
Measurement
Test-
Unit Terminal Unit
Rear
ANT
panel
Adjustment
Specifi cations /
Parts
Method
[Panel
Make the demodu-
tuning
lation waves into
mode]
square waves.
[PF3]
[PF4]
[PC test
mode]
[ ],[ ]
4000Hz
±50Hz
2000Hz
±50Hz
Set it the adjust-
ment value obtained
from the [Max Devi-
ation Adjust [Wide]
adjustment of step
6.
2827Hz
2771~2883Hz
Set it the ad-
justment value
obtained from the
[Max Deviation
Adjust [Narrow]
adjustment of step
6.
Remarks

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tk-5810hTk-5810bgTk-5810hbg

Table of Contents