NEC Express5800 Series Maintenance Manual page 196

Express server
Hide thumbs Also See for Express5800 Series:
Table of Contents

Advertisement

Chapter 3 Appendix
Error Message
9021
Unsupported CPU Speed detected
on CPU #1
9022
Unsupported CPU Speed detected
on CPU #2
9040
PEI_CPU_SELF_TEST_FAILED
9041
Detected CPU Error on CPU #1
9042
Detected CPU Error on CPU #2
9060
PEI_CPU_MISMATCH
9080
Link in Slow Speed Mode between
CPU1 and CPU2.
9081
Link Failure between CPU1 and
CPU2.
9082
Link Width Error between CPU1
and CPU2.
9E80
Forced to use CPU with error. A CPU error occurred, but forced to
A001
Memory Error detected in
CPU1_DIMM1
A002
Memory Error detected in
CPU1_DIMM2
A003
Memory Error detected in
CPU1_DIMM3
A004
Memory Error detected in
CPU1_DIMM4
A005
Memory Error detected in
CPU1_DIMM5
A006
Memory Error detected in
CPU1_DIMM6
A00D
Memory Error detected in
CPU2_DIMM1
A00E
Memory Error detected in
CPU2_DIMM2
A00F
Memory Error detected in
CPU2_DIMM3
A010
Memory Error detected in
CPU2_DIMM4
A011
Memory Error detected in
CPU2_DIMM5
A012
Memory Error detected in
CPU2_DIMM6
A420
Online Spare Memory was not
ready.
A421
Mirroring Memory was not
ready.
A423
Lockstep was not ready.
A42
Cluster On Die was not
8
ready.
A42
DIMM population is
9
insufficient for Cluster On
Die.
A800
Memory not detected
A804
Latest memory module is
corrupted.
AE01
CPU1_DIMM1 has been disabled. A memory error was detected.
CPU1_DIMM2 has been disabled. A memory error was detected.
AE02
196
Cause
A CPU having an unsupported clock
speed was detected.
An error occurred in CPU
initialization.
An error occurred on CPU #1.
An error occurred on CPU #2.
The type of CPU in slot CPU#1
differs from that in CPU#2.
Slow Speed Mode was detected on
a bus between CPU1 and CPU2.
Link failure was detected on a bus
between CPU1 and CPU2.
Link width error was detected on a
bus between CPU1 and CPU2
use the CPU.
An error was detected on
CPU1_DIMM1.
An error was detected on
CPU1_DIMM2.
An error was detected on
CPU1_DIMM3.
An error was detected on
CPU1_DIMM4.
An error was detected on
CPU1_DIMM5.
An error was detected on
CPU1_DIMM6.
An error was detected on
CPU2_DIMM1.
An error was detected on
CPU2_DIMM2.
An error was detected on
CPU2_DIMM3.
An error was detected on
CPU2_DIMM4.
An error was detected on
CPU2_DIMM5.
An error was detected on
CPU2_DIMM6.
Failed to enable the Sparing feature
by the current memory
configuration.
Failed to enable the Mirroring
feature by the current memory
configuration.
Failed to enable the LockStep
feature by the current memory
configuration.
Failed to enable the Cluster On Die
feature by the current hardware
configuration.
Failed to enable the Cluster On Die
feature by the current memory
configuration.
No available memory is installed.
The BIOS flash memory was failed.
CPU1_DIMM1 has been disabled.
CPU1_DIMM2 has been disabled.
Express5800/B120f Maintenance Guide
1. Error Message of POST and Virtual LCD
Solution
Contact your sales representative.
Start SETUP, and confirm the settings of
Memory RAS Mode. When Memory
Sparing, Memory Mirroring, or Memory
LockStep feature is enabled, POST
detects this error if DIMMs are degraded.
Start SETUP, and specify Yes for
Memory Retest, then execute Save
Changes and Exit. If the same error
persists, contact your sales
representative.
Replace with a processor that supports
this feature, or start SETUP and disable
Cluster On Die. If this does not resolve
the problem, contact your sales
representative.
Check if the memory configuration is
proper. If this does not resolve the
problem, contact your sales
representative.
Check if DIMMs are properly installed. If
the same error persists, contact your sales
representative.
Contact your sales representative.