NEC Express5800 Series Maintenance Manual page 204

Express server
Hide thumbs Also See for Express5800 Series:
Table of Contents

Advertisement

Chapter 3 Appendix
Messages displayed on a lower LCD line
BMC Message on Lower LCD Line
ProcessorX Voltage Lower Non-Critical
(X: 1 or 2)
ProcessorX Voltage Upper Non-Critical
(X: 1 or 2)
ProcessorX Voltage Lower Critical (X:
1 or 2)
ProcessorX Voltage Upper Critical (X:
1 or 2)
BaseBoard Voltage Lower Non-Critical
BaseBoard Voltage Upper Non-Critical
BaseBoard Voltage Lower Critical
BaseBoard Voltage Upper Critical
VBAT Lower Non-Critical
VBAT Upper Non-Critical
VBAT Lower Critical
VBAT Upper Critical
Baseboard Temperature1 Lower
Non-Critical
Baseboard Temperature1 Upper
Non-Critical
Baseboard Temperature1 Lower
Critical
Baseboard Temperature1 Upper
Critical
CPUX_DIMM Area Temperature Upper
Non-Critical (X: 1 or 2)
CPUX_DIMM Area Temperature Upper
Critical (X: 1 or 2)
ProcessorX Thermal Control Upper
Non-Critical (X: 1 or 2)
ProcessorX Thermal Control Upper
Critical (X: 1 or 2)
ProcessorX Thermal Trip (X: 1 or 2)
Insufficient Cooling Error (Not Power
ON)
DUMP Request !
Processor Missing
Chip Set Thermal Trip
CPU1_DIMMX Uncorrectable Error (X:
number)
CPU2_DIMMX Uncorrectable Error (X:
number)
ProcessorX Internal Error (X: 1 or 2)
204
Cause
A voltage abnormality was
detected.
A temperature abnormality was
detected.
A temperature abnormality was
detected.
The power was forcibly turned off
due to a CPU temperature
abnormality.
In the Blade Enclosure, the
number of fans installed is
insufficient or the installed fan is
faulty. Thus, the CPU blade
failed to power on due to
insufficient cooling power.
DUMP switch is pressed.
No CPU is installed in CPU
socket.
The power was forcibly turned off
due to a chipset temperature
abnormality.
An uncorrectable error occurred
on DIMM for CPU #1.
X: Failed DIMM number (1-origin)
An uncorrectable error occurred
on DIMM for CPU #2.
X: Failed DIMM number (1-origin)
An internal CPU error (IERR)
occurred.
Express5800/B120f Maintenance Guide
1. Error Message of POST and Virtual LCD
Solution
Contact your sales representative.
Check if fans in Blade Enclosure work
normally. Refer to the User's Guide of
the Blade Enclosure to make sure that
the sufficient number of fans is
installed, and CPU blades and fan units
are installed in correct locations. Check
installation status of heat sink of the
CPU blade. Check if ambient
temperature of installation location
satisfies the operation guarantee
condition. If this does not resolve the
problem, contact your sales
representative.
Wait until completion of memory dump
process.
Check installation status of the CPU
blade. If this does not resolve the
problem, contact your sales
representative.
Contact your sales representative.
Contact your sales representative.