Toro GreensPro 1240 Service Manual page 37

Hide thumbs Also See for GreensPro 1240:
Table of Contents

Advertisement

Traction Circuit Problems (GreensPro 1260)
(continued)
Problem
No traction exists in either direction.
The hydraulic motor does not hold load
in the N
position.
EUTRAL
GreensPro
1240/1260
14211SL Rev A
Possible Cause
The hydraulic fluid level in the hydraulic
tank is low.
The hydraulic pump tow (bypass) valve
is open or damaged.
The charge pressure is low.
The motion control linkage is incorrectly
adjusted, disconnected, binding, or
damaged.
The hydraulic pump relief valves are
leaking or damaged.
The hydraulic pump is worn or
damaged.
The hydraulic drive motor is worn or
damaged.
Note: If a traction circuit component
has internal wear or damage, it
is possible that the other traction
components are also damaged.
The charge pressure is low.
The hydraulic pump relief valves are
leaking or damaged.
The hydraulic pump is worn or
damaged.
The hydraulic drive motor is worn or
damaged.
Note: If a traction circuit component
has internal wear or damage, it
is possible that the other traction
components are also damaged.
Page 3–7
Corrective Action
Adjust the hydraulic fluid level.
Close or replace the hydraulic pump
bypass valve.
Verify charge pressure; refer to
Hydraulic Pump Charge Pressure Test
in Chapter 5 – Hydraulic System.
Verify motion control operation and
repair or adjust as necessary; refer
to Adjusting the Control Pedal Return
to Neutral Mechanism in Chapter 5 –
Hydraulic System.
Verify hydraulic pump relief valve
operation; refer to Hydraulic Pump
Flow and Relief Pressure Test in
Chapter 5 – Hydraulic System.
Verify hydraulic pump operation; refer
to Hydraulic Pump Flow and Relief
Pressure Test in Chapter 5 – Hydraulic
System.
Repair or replace the hydraulic drive
motor.
Verify charge pressure; refer to
Hydraulic Pump Charge Pressure Test
in Chapter 5 – Hydraulic System.
Verify hydraulic pump relief valve
operation; refer to Hydraulic Pump
Flow and Relief Pressure Test in
Chapter 5 – Hydraulic System.
Verify hydraulic pump operation; refer
to Hydraulic Pump Flow and Relief
Pressure Test in Chapter 5 – Hydraulic
System.
Repair or replace the hydraulic drive
motor.
Troubleshooting: Traction Circuit Problems
(GreensPro 1260)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greenspro 44812Greenspro 1260Greenspro 44913