Examples Of Replacing Components - Siemens SINAMICS S120 Function Manual

Drive functions
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Basic information about the drive system
13.9 Component replacement
Replacing motors with SINAMICS Sensor Module Integrated or with DRIVE-CLiQ Sensor Integrated
If a defect has occurred in a motor with integrated DRIVE-CLiQ interface (SINAMICS Sensor
Module Integrated), please contact the Siemens office in your region to arrange for repair.
13.9.2

Examples of replacing components

Example: Replacing a component with different article number
Requirement:
● The replaced component has a different article number
Table 13- 7
Action
The component has been successfully replaced.
992
Example: Replacing a component with different article number
Switch off the power supply
Replace the defective com-
ponent and connect the new
one
Switch on the power supply
Load the project from the
Control Unit to the
STARTER (PG)
Configure the replacement
drive and select the current
component
Load the project to the Con-
trol Unit (target system)
Reaction
Alarm A01420
Alarm disappears
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
Remark
The new article number is
stored in the RAM of the Control
Unit and has to be copied to the
non-volatile memory with
p0977 = 1 and p0971 = 1. As an
alternative, STARTER can be
used to backup data with a RAM
to ROM operation.
Drive functions

Hide quick links:

Advertisement

Table of Contents
loading