Siemens SINAMICS S120 Function Manual page 753

Drive functions
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Characteristics of the parameter channel
● One 16-bit address exists for each parameter number and subindex.
● Concurrent access by several additional PROFIBUS masters (master class 2) or
PROFINET IO supervisor (e.g. commissioning tool).
● Transfer of different parameters in one access (multiple parameter request).
● Transfer of complete arrays or part of an array possible.
● Only one parameter request is processed at a time for each controller/device connection
(no pipelining).
● A parameter request/response must fit into a data set (e.g. PROFIBUS: Max. 240 bytes).
● The request or the response header is user data.
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
Figure 11-8
Reading and writing data
11.1 Communication according to PROFIdrive
Communication
753

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents