Basic information about the drive system
13.9 Component replacement
Example: Replacing a Motor Module/Power Module with a different power rating
Requirements:
● The replaced power unit has a different power rating
● Vector: Power of the Motor Module/Power Module not greater than 4 motor current
Table 13- 9
Action
•
•
•
•
•
The component has been successfully replaced.
994
Example: Replacing a power unit with a different power rating
Switch off the power supply
Replace the defective compo-
nent and connect the new one
Switch on the power supply
Drive object CU:
–
p0009 = 1
–
p9906 = 2
–
p0009 = 0
–
p0977 = 1
Drive object component:
–
p0201 = r0200
–
p0010 = 0
–
p0971 = 1
Reaction
Alarm A01420
•
Device configuration
•
Component comparison
•
Completing the configuration
•
Data backup
•
Use the code number
•
Completing commissioning
•
Data backup
•
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
Remark
For p9906 = 2: Caution
Topology monitoring for all
(!) components has been
significantly reduced, so that
if DRIVE-CLiQ lines are
accidentally changed over
this will not be detected.
The new article number is
stored in the RAM of the
Control Unit and has to be
copied to the non-volatile
memory with p0977 = 1 and
p0971 = 1. As an alternative,
STARTER can be used to
backup data with a RAM to
ROM operation.
Drive functions