Siemens SINAMICS S120 Function Manual page 666

Drive functions
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Monitoring functions and protective functions
9.5 Thermal motor protection
• p4108[0...5]
• p4109[0...11]
• p4110[0...11]
• p4111[0...2]
• r4112[0...2]
• r4113[0...2]
• r4114[0...2]
• p4117[0...2]
• p4118[0...11]
• p4119[0...11]
• r4120[0...11]
• p4121
• p4122[0...11]
Thermal motor models
• p0318[0...n]
• p0335[0...n]
• p0344[0...n]
• p0611[0...n]
• p0612[0...n]
• p0615[0...n]
• p0617[0...n]
• p0618[0...n]
• p0619[0...n]
• p0620[0...n]
• p0625[0...n]
666
TM150 terminal block measurement method
TM150 cable resistance measurement
TM150 cable resistance value
TM150 group channel assignment
CO: TM150 group, temperature actual value maximum value
CO: TM150 group, temperature actual value minimum value
CO: TM150 group actual temperature value, average
TM150 group, sensor fault effect
TM150 fault threshold / alarm threshold hysteresis
TM150 activate/deactivate smoothing
TM150 actual value smoothing time in ms
TM150 filter, rated line frequency
TM150 smoothing time constant
Motor stall current
Type of motor cooling
Motor weight (for thermal motor type)
I2t motor model thermal time constant
Mot_temp_mod activation
Mot_temp_mod 1 (I2t) fault threshold
Stator thermally relevant iron component
Stator thermally relevant copper component
Rotor thermally relevant mass
Thermal adaptation, stator and rotor resistance
Motor ambient temperature during commissioning