Basic functions
7.20 Tolerant encoder monitoring
7.20.15

Overview of important parameters

Overview of important parameters (see SINAMICS S120/S150 List Manual)
• p0404[0...n]
• p0405[0...n]
• p0408[0...n]
• p0430[0...n]
• p0437[0...n]
• p0438[0...n]
• r0452[0...2]
• r0458[0...2]
• r0459[0...2]
• p4680[0...n]
• p4681[0...n]
• p4682[0...n]
• p4683[0...n]
• p4684[0...n]
• p4686[0...n]
• r4688[0...2]
• r4689[0...2]
386
Encoder configuration active
Square-wave encoder track A/B / square-wave encoder A/B
Rotary encoder pulse No.
Sensor Module configuration
Sensor Module extended configuration
Square-wave encoder filter time
Square-wave encoder filter time display
Sensor Module properties
Sensor Module extended properties
Zero mark monitoring tolerance permissible
Zero mark monitoring tolerance window limit 1 positive
Zero mark monitoring tolerance window limit 1 negative
Zero mark monitoring tolerance window alarm threshold positive
Zero mark monitoring tolerance window alarm threshold negative
Zero mark, minimum length
CO: Zero mark monitoring, number of differential pulses
CO: Square-wave encoder diagnostics
Function Manual, 11/2017, 6SL3097-4AB00-0BP5