Drive functions
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Servo control
4.4 Speed controller
Example of speed-dependent adaptation
Note
This type of adaptation is only active when the drive is operated with an encoder!
Figure 4-5
Parameterization with STARTER
The "Speed controller" parameter screen is selected with the
STARTER commissioning tool.
Function diagrams (see SINAMICS S120/S150 List Manual)
• 5050
Overview of important parameters (see SINAMICS S120/S150 List Manual)
Free Kp_n adaptation
• p1455[0...n]
• p1456[0...n]
• p1457[0...n]
• p1458[0...n]
• p1459[0...n]
94
Speed controller-K
/T
p_n
n_n
Servo control - Speed controller adaptation (K
CI: Speed controller P gain adaptation signal
Speed controller P gain adaptation lower starting point
Speed controller P gain adaptation upper starting point
Lower adaptation factor
Upper adaptation factor
adaptation
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
icon in the toolbar of the
-/T
adaptation)
p_n
n_n
Drive functions

Hide quick links:

Advertisement

Table of Contents
loading