Changing the view of the screen form
The view of this screen form can be reduced to the essentials via a checkbox. Changing the
function of one of the bidirectional digital inputs/outputs is not possible in the optimized view.
The view of the screen form can also be switched to a simulation mode. This switchover only
functions in online mode.
1. If you want to optimize the view, activate the "Optimize view" option.
2. If you want to switch to a simulation from the terminal evaluation, select "Simulation" in
the drop-down list of a digital input.
Parameterizing digital inputs 8 ... 15 or digital outputs 8 ... 15
Each of the bidirectional digital inputs/outputs can be parameterized as an input or output
using the selector.
Selector position
Digital input
Digital output
1. Select the digital input/output on the required terminal.
2. Connect the signal source of the digital input (8 ... 15).
- Or -
3. To change the digital input to a digital output, proceed as follows:
– Click the selector.
– Then connect the signal sink of the digital output (8 ... 15).
– Invert the digital output when required.
4. Repeat steps 2 or 3 for all digital inputs/outputs of the required terminal.
Commissioning with Startdrive
Commissioning Manual, 11/2017, 6SL3097-4AA10-0BP1
Description
Default setting when calling the screen form the first time.
Digital inputs 8 ... 15 can be interconnected with this switch position. Several
interconnections are possible.
The selector can be switched by clicking from digital input to digital output.
Digital outputs 8 ... 15 can be interconnected with this switch position. Several
interconnections are possible.
The selector can be switched by clicking from digital output to digital input.
4.7 Basic parameterization of the drive objects
Commissioning
169