Siemens SINAMICS S120 Commissioning Manual page 235

With startdrive
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

2. Click the
The "Control" screen form opens. The display of the screen form depends on the basic
settings of the Safety Integrated Extended Functions.
In this screen form, configure the controls via the fail-safe inputs and outputs and/or
PROFIsafe (see Section "Control (Page 281)").
Figure 4-97
3. Call the "STO/SBC" safety functions again.
4. Then connect the signal source r9773.1 for the "STO active in the drive" function.
5. Click the
The "Brake control" screen form opens.
Figure 4-98
Configure the brake control here (see Section "Brake control (Page 288)").
6. Click "Save project" in the toolbar to save the changes in the project.
Result
You have configured the "STO/SBC" safety functions.
Commissioning with Startdrive
Commissioning Manual, 11/2017, 6SL3097-4AA10-0BP1
button (Select STO) to configure activation of the "STO" function.
Example: Control of STO
button (brake control) to configure the "SBC" function.
Example: Brake control without motor holding brake