Connecting
6.6 Connecting the heating elements and three-phase line supply
POM4320
Position of the connections
84
Pin assignments X1 to X6
X1
3-pin plug for L1:
Power output 1 ... 3 outgoing
X2
3-pin plug for L2:
Power output 4 ... 6 outgoing
X3
3-pin plug for L3:
Power output 7 ... 9 outgoing
X4
3-pin plug for L2:
Power output 1 ... 3 incoming
X5
3-pin plug for L3:
Power output 4 ... 6 incoming
X6
3-pin plug for L1:
Power output 7 ... 9 incoming