Setting The Operation Mode; Setting The Operation Mode For The Crosspoint Buttons; Setting The Transition Operation Mode - Panasonic Live Production Suite Series Operating Manual

Gateway/spt/me/system manager unit, menu/control panel optional
Table of Contents

Advertisement

Setting the operation mode

Setting the operation mode for the crosspoint buttons

Selecting a bus using the SHIFT function
The SHIFT function is used to assign four sources to one crosspoint button (the KEY, PGM/A, or PST/B bus crosspoint button) and change pages using
the <2nd PAGE>/<3rd PAGE> buttons on the right of the source name display panel.
There are two operation methods for the SHIFT function:
All SHIFT
Single SHIFT
The <2nd PAGE>/<3rd PAGE> buttons can be used in two modes.
1
Select the <OPR> button → [OTHER SETTINGS] → [Page Mode] tab.
2
Set an item in [2nd Page Button] and [3rd Page Button] in the [Page Mode] column.
[Normal]
[Page Lock]
Assign the SHIFT function to the crosspoint buttons
1
Select the <PANEL> button → [XPT ASSIGN] → [Panel1]/[Panel2]/[Panel3] tab.
[Panel1] tab
[Panel2] tab
[Panel3] tab
2
Select the buttons to assign the SHIFT function from the button list in the left column.
f For details on the button assignment of the crosspoint area, refer to "Assigning signals to buttons".
3
Select [2nd Page] or [3rd Page] from the signal list in the right column.
f [2nd Page] and [3rd Page] are displayed when [Special] is selected in [Page Select].
4
Select [Assign].
f The SHIFT function is assigned to the button selected in the step
f Once the assignment is set on one page, the corresponding button on other pages works in a same way.
Selecting the bus mode
Select the A/B bus system or the flip-flop system (PGM/PST system).
1
Select the <OPR> button → [OTHER SETTINGS] → [Bus Mode] tab.
2
Set an item in [Bus Mode Type] in the [Bus Mode] column.
[Common]
[Each]

Setting the transition operation mode

Setting the time display unit
The time display unit used in this unit can be set as a second/frame basis or a frame basis.
1
Select the <OPR> button → [OTHER SETTINGS] → [Transition] tab.
2
Select an item in [Time Unit] in the [Time Unit] column.
[Sec/Frame]
[Frame]
f The maximum possible setting time is 16s19f (499 frames).
Chapter 7 Configuring Operations — Setting the operation mode
Use the <2nd PAGE>/<3rd PAGE> buttons to change all source pages for the crosspoint buttons included in the
corresponding ME at once.
Operate by assigning the <2nd PAGE>/<3rd PAGE> button to the crosspoint buttons with the menu.
Use the assigned button to change the source page of the crosspoint buttons included in the corresponding ME on a bus
basis. In this case, the <2nd PAGE>/<3rd PAGE> buttons on the right of the source name display panel can be used to
switch the source name displays.
Enabled only while the button is pressed.
Enabled and disabled every time the button is pressed.
Assigns the control panel 1.
Assigns the control panel 2 (second Control Panel).
Assigns the control panel 3 (third Control Panel).
Sets the same bus mode in ME1 and ME2.
Setting of the [Bus Mode] column → [Bus Mode] is applied to both ME1 and ME2.
Different bus modes can be set for ME1 and ME2.
Settings of the [Each Bus Mode] column → [Bus Mode ME1] and [Bus Mode ME2] are applied to ME1 and ME2
respectively.
Sets the time display unit as a second/frame basis.
Sets the time display unit as a frame basis.
2
.