Error code
Error name
D232H
CC-Link IE Field Network function
related errors
D234H
CC-Link IE Field Network function
related errors
D235H
CC-Link IE Field Network function
related errors
D238H
CC-Link IE Field Network function
related errors
D239H
CC-Link IE Field Network function
related errors
D23AH
CC-Link IE Field Network function
related errors
D23BH
CC-Link IE Field Network function
related errors
D23CH
CC-Link IE Field Network function
related errors
D23DH to D23EH
CC-Link IE Field Network function
related errors
D244H
CC-Link IE Field Network function
related errors
D246H
CC-Link IE Field Network function
related errors
D25DH
CC-Link IE Field Network function
related errors
D273H
CC-Link IE Field Network function
related errors
D280H
CC-Link IE Field Network function
related errors
Description
No target station for which to change station
number.
Baton pass not carried out.
Transient transmission error detected.
Transmission queue full.
Failure in SLMP transmission.
There is an error in the SLMP sub-header.
There is an error in the SLMP network
number.
There is an error in the SLMP target station
number.
There is an error in the SLMP request data.
Invalid transient transmission data.
Invalid transient transmission data.
Invalid transient transmission data.
Error in the transient transmission data size.
Error in the transient transmission request
command.
Corrective action
• No station for which to carry out station
number change.
• Check if the station number is not set in
the station for which to carry out station
number change.
Check the communications status.
• In engineering tools CC-Link IE Field
diagnoses, check the network status, and
take measures.
• Check that there are no faults with the
cable or a switching hub connections.
• If the error code is displayed again even
after taking an action, consult your local
Mitsubishi representative.
• Temporarily interrupt transient
transmission, and try again.
• Lower the transient transmission usage
frequency, and then perform again.
• If the error code is displayed again even
after taking an action, consult your local
Mitsubishi representative.
• Wait some time before executing again.
• If the error code is displayed again even
after taking an action, consult your local
Mitsubishi representative.
Correct the sub-header information at the
request source, and then run again.
Correct the network number at the request
source, and run again.
Correct the station number at the request
source, and then run again.
There is an error in the device information
acquisition request of "CC IE Field
Configuration Setting" displayed in the
"Network Configuration Settings" of the
"Basic Setting" of the engineering tool.
Close the "CC IE Field Configuration
Setting", and then request again.
• Correct the transient data at the transient
request source, and run again.
• If the error code is displayed again even
after taking an action, consult your local
Mitsubishi representative.
• Correct the transient data at the transient
request source, and run again.
• If the error code is displayed again even
after taking an action, consult your local
Mitsubishi representative.
• Correct the transient data at the transient
request source, and run again.
• If the error code is displayed again even
after taking an action, consult your local
Mitsubishi representative.
• Correct the request command at the
transient request source, and run again.
• If the error code is displayed again even
after taking an action, consult your local
Mitsubishi representative.
Correct the request command at the
transient request source, and run again.
APPX