7.2
Reserved Station Specification
Reserved station specification can reserve stations to connect in the future (not actually connected, but those counted as
being on the network).
Reserved stations do not become faulty stations even if they are not actually connected.
(2)
(1) Master station
(2) Slave station 1
(3) Slave station 2
(4) Slave station 3 (not actually connected reserved station)
Setting method
In network configuration settings, specify the slave station as a reserved station. ( Page 177 Network Configuration
Settings)
Reserve station settings such as occupied station number and IP address can also be input.
(1)
(3)
(4)
7 CC-Link IE Field Network Basic FUNCTION
7.2 Reserved Station Specification
7
89