Error Messages and Trouble-Shooting
9.4
Error Indication on the ERR-LED
Some error states are not only indicated with error_code on the FC 56 but
simultaneously also with the ERR-LED on the interface module.
The ERR-LED indicates error messages with a flashing pattern (see table 9-3)
followed by break in flashing. This sequence is repeated continuously.
The ERR-LED is reset (flashing pattern disappears) by the following.
S Turning off the ASM (for all ASMs)
S Init_run command (for ASM 473 and ASM 475)
Table 9-3
Error indications of the ERR-LED
Flashing
Filehandler
of the
Error Message
ERR-LED
1x
D0 01
2x
C0 06
3x
B0 01
4x
C0 02
5x
C0 07
6x
C0 08
7x
C0 09
8x
C0 10
9x
C0 11
10x
C0 12
11x
C0 13
12x
C0 14
13x
C0 15
14x
C0 16
15x
C0 17
20x
– – – –
9-12
Only RESET command permitted (ASM startup)
Presence error
Error in connection with the SLG
Error on the RAM of the MDS
Parameterization error for TRACE or FORMAT/command cannot be interpreted.
Too many sync attempts
Too many sending errors
CRC sending error
FORMAT, CRC error while receiving
FORMAT, MDS cannot be initialized.
FORMAT, timeout
FORMAT, not initialized
CMD address error
ECC error
General driver error
Internal ASM overflow
Meaning