MOBY Commands
4.2.19
LOAD
Parameterizing the command in Command_DB
Table 4-28
UDT 50 "MOBY FH CMD" – LOAD
Address
Name
0.0
+0.0
UID
+4.0
command
+5.0
sub_command_1
+6.0
sub_command_2
+7.0
sub_command_3
+8.0
Filename
+16.0
length
+20.0
address_MDS
+22.0
DAT_DB_number
+24.0
DAT_DB_address
+26.0
QUEUE_DB_number
+28.0
QUEUE_DB_address 0
=30.0
Acknowledgment data in the LOAD command
The LOAD command does not generate user data in the acknowledgment.
4-32
Starting
Commentary
Value
DW#16#0
Not used
'O'
MDS command: O = LOAD
B#16#0
Not used
B#16#0
Not used
B#16#0
Not used
'xxxxxxxx'
Not used
L#1
Length of the data to be transferred. Enter the
length here which was supplied by the MOVE com-
mand as the result.
W#16#0
Not used
48
Data DB. The LOAD data must be stored in this
DB.
0
Address of the beginning of the user data in
the data DB
48
Not used