The following data records have been implemented on the MOBY-ASM for
communication.
Table B-3
Data
Record No.
0
1
101
102
111
112
150
151
239
246
248
255
Data record 10x
Each of data records (DR) 101 and 102 parameterizes one MOBY channel.
DR 10x must contain a RESET command. After the module starts up, DR 10x
must be sent to each MOBY channel. The channel is not ready for operation until
this is done.
A DR 10x is also accepted during normal operation. DR 10x interrupts a running
command. The user receives no further acknowledgment for the interrupted
command.
Data record 11x
DRs 111 and 112 are used for sending the actual commands and related
acknowledgments (all commands except RESET).
FC 56
J31069-D0155-U001-A0-7618
Programming MOBY-ASM on PROFIBUS-DP-V1
Data record numbers
Present on MOBY-ASM
All
All
All
ASM 475
All
ASM 475
ASM 475, 473
ASM 475, 473
ASM 475, 473
ASM 475, 473
ASM 475, 473
All
Description
Reserved
Reserved
Parameterization channel 1
Parameterization channel 2
Data transmission channel 1
Data transmission channel 2
Reserved (diagnosis of power
parameters)
Reserved (diagnostic buffer)
FW update (optional)
Reserved (read FW version)
Reserved (SZL list)
Reserved
B-27