Siemens MOBY FC 56 Technical Description page 54

Table of Contents

Advertisement

MOBY Commands
Acknowledgment data in the MDS-STATUS command
Starting at address DAT_DB_address, data block DAT_DB_number contains the
required data. These data are defined in an UDT so that the user can evaluate the
information.
Presentation of the MDS data in UDT 100 with sub_command_1 = 00
Table 4-19
UDT 160 "MDS STATUS FH"
Address
Name
0.0
+0.0
UID
+4.0
MDS_name
*1.0
+12.0
MDS_type_FH
+14.0
MDS_capacity
+18.0
Free_capacity
+22.0
Free_directory
+24.0
ANZ_res0
+24.1
ANZ_res1
+24.2
Battery_low
+24.3
LR_bat
+24.4
ANZ_res4
+24.5
ANZ_res5
+24.6
ANZ_res6
+24.7
ANZ_MDS_covered
+26.0
Cycles_write
+30.0
ECC_corrections
=32.0
4-24
Type
Commentary
STRUCT
DINT
MDS number
ARRAY [1..8]
Name of the MDS which was transferred in FORMAT
CHAR
BYTE
Logical format identifier of the MDS (filehan-
dler format). See table 1-1 for the logical
file structure behind this parameter.
Without ECC
04
05
06
DINT
Memory size of the MDS in bytes
DINT
Amount of memory on the MDS in bytes
INT
Free directory entries on the MDS
BOOL
BOOL
BOOL
Set: MDS or RAM battery must be replaced (only
MOBY I).
BOOL
Set: Communication battery of MDS 507 must be
replaced (only MOBY I).
BOOL
BOOL
BOOL
BOOL
Set: Since the MDS is locked with the COVER
command, its structure cannot be changed.
DINT
Number of SLG stations which have been pro-
cessed with this MDS since the first time it
was formatted
BYTE
Number of automatically executed ECC offsets
since the first time the MDS was formatted
END_STRUCT
With ECC
Memory Size
84
2 kbytes
85
8 kbytes
86
32 kbytes
J31069-D0155-U001-A0-7618