Siemens MOBY FC 56 Technical Description page 49

Table of Contents

Advertisement

4.2.9
COVER
Parameterizing the command in Command_DB
Table 4-14
UDT 50 "MOBY FH CMD" – COVER
Address
Name
0.0
+0.0
UID
+4.0
command
+5.0
sub_command_1
+6.0
sub_command_2
+7.0
sub_command_3
+8.0
Filename
+16.0
length
+20.0
address_MDS
+22.0
DAT_DB_number
+24.0
DAT_DB_address
+26.0
QUEUE_DB_number
+28.0
QUEUE_DB_address 0
=30.0
Acknowledgment data in the COVER command
The COVER command does not generate user data in the acknowledgment.
FC 56
J31069-D0155-U001-A0-7618
Starting
Commentary
Value
DW#16#0
MDS number, only MOBY U with multitag
'C'
MDS command: C = Cover MDS
B#16#0
Specify use of the MDS (user)
00H
Change of MDS file structure later is permitted.
01H
The MDS is locked against "unauthorized access."
B#16#0
Not used
B#16#0
Not used
'TEST-MDS'
MDS name
Character and/or digit combination in ASCII format. The MDS
must be addressed with its MDS name which was specified in
FORMAT. The MDS name can be obtained with the command
MDS-STATUS.
L#1
Not used
W#16#0
Not used
48
Not used
0
Not used
48
Not used
Not used
MOBY Commands