The Parameter Data Block
Table 3-1

UDT 10 "MOBY Param"

Address
Name
0.0
+0.0
ASM_address
+2.0
ASM_channel
+4.0
command_DB_number
+6.0
command_DB_address
+8.0
MDS_IO_control
+9.0
ECC_mode
+9.1
reserved01
+9.2
Priority_RW
+9.3
Priority_RWD
+10.0
MOBY_mode
+11.0
scanning_time
+12.0
SLG_number
+14.0
distance_limiting
+15.0
multitag
+16.0
field_ON_control
+17.0
field_ON_time
+18.0
ANZ_MDS_present
+18.1
ANZ_DIR_change
+18.2
ANZ_ECC
+18.3
ANZ_Read_0
+18.4
LR_bat
+18.5
battery_low
+18.6
error
+18.7
ready
+19.0
reserved02
+19.1
command_start
+19.2
reserved03
+19.3
init_run
+19.4
ASM_failure
+19.5
FC56_active
+19.6
ANZ_next
+19.7
ANZ_reset
+20.0
ASM_busy
+20.1
reserved04
+20.2
ANZ_presence_change
+20.3
ANZ_MDS_lost
+21.0
number_MDS
+22.0
error_code
+26.0
version_MOBY
+30.0
to
+299.0
=300.0
3-2
Type
Starting
Commentary
Value
STRUCT
INT
0
Input:address of ASM (cycle word)
INT
1
Input: number of channel (1 to 4)
INT
47
Input:number of command DB
INT
0
Input:first address of commands in the
command DB
BYTE
B#16#1
Input:setup the MDS controlling
(0, 1, 4, 5)
BOOL
FALSE
Input: working with ECC check
BOOL
FALSE
BOOL
FALSE
Input: TRUE = Read and write commands
are allowed.
BOOL
FALSE
Input: TRUE = Read, write and delete
commands are allowed.
BYTE
B#16#1
Input: MOBY working mode (1, 4, 5, 6)
BYTE
B#16#0
Input: scan time for long-range
MOBY I/U
WORD
W#16#FFFF Input: number of the SLG station
BYTE
Input: range limit
B#16#F
BYTE
Input: max. no. of MDS permitted in
B#16#1
field
BYTE
Input: working mode of BERO
B#16#0
BYTE
B#16#0
Input: time has be of BERO
BOOL
FALSE
MDS is present
BOOL
FALSE
MDS with new directory
BOOL
FALSE
Error correction done
BOOL
FALSE
Warning: Read file has length of 0.
BOOL
FALSE
battery of the MDS 507
BOOL
FALSE
battery check has indicated low
voltage
BOOL
FALSE
error during command processing has
appeared
BOOL
FALSE
command chain has been finished
BOOL
FALSE
BOOL
FALSE
set: startup signal for command or
command chain
BOOL
FALSE
BOOL
TRUE
set: Reset ASM and parameterize again
BOOL
FALSE
OB122 set: ASM removed from PROFIBUS
BOOL
FALSE
FC is active
BOOL
FALSE
last command was NEXT
BOOL
FALSE
last command was RESET
BOOL
FALSE
a command is processed by ASM
BOOL
FALSE
BOOL
FALSE
An MDS entered the field or left the
field.
BOOL
FALSE
Warning: MDS left the field while be-
ing processed.
BYTE
B#16#0
number of MDS actual in field
DWORD
Error indication of interface module
or FC
ARRAY
W#16#0
firmware version of MOBY
Internal FC variables. May not be
changed by the user.
END_
STRUCT
FC 56
J31069-D0155-U001-A0-7618