4.2.14
GET
Parameterizing the command in Command_DB
Table 4-22
UDT 50 "MOBY FH CMD" – GET
Address
Name
0.0
+0.0
UID
+4.0
command
+5.0
sub_command_1
+6.0
sub_command_2
+7.0
sub_command_3
+8.0
Filename
+16.0
length
+20.0
address_MDS
+22.0
DAT_DB_number
+24.0
DAT_DB_address
+26.0
QUEUE_DB_number
+28.0
QUEUE_DB_address 0
=30.0
Acknowledgment data in the GET command
The user data contained in the acknowledgment of the GET command are written
to the address parameterized in the command. The acknowledgment data are
stored in the structure shown below.
Table 4-23
UDT 200 "MOBY UID4"
Address
Name
0.0
+0.0
Reserved
+1.0
Number_MDS
+2.0
UID
*4.0
=50.0
FC 56
J31069-D0155-U001-A0-7618
Starting
Commentary
Value
DW#16#0
Not used
'P'
Command: P = GET. Fetch UIDs of all MDSs
located in the field.
B#16#0
Not used
B#16#0
Not used
B#16#0
Not used
'xxxxxxxx'
Not used
L#1
Not used
W#16#0
Not used
48
Data DB. The status data are written to this
DB.
0
Address of the beginning of the user data in
the data DB
48
Not used
Not used
Type
Commentary
STRUCT
BYTE
BYTE
Number of MDSs located in the field. This is
also the number of valid UID entries in the
ARRAY which follows.
ARRAY [1..12] MDS number (unique identifier)
DWORD
END_STRUCT
MOBY Commands