MOBY Commands
4.2.13
TRACE
Parameterizing the command in Command_DB
Table 4-21
UDT 50 "MOBY FH CMD" – TRACE
Address
Name
0.0
+0.0
UID
+4.0
command
+5.0
sub_command_1
+6.0
sub_command_2
+7.0
sub_command_3
+8.0
Filename
+16.0
length
+20.0
address_MDS
+22.0
DAT_DB_number
+24.0
DAT_DB_address
+26.0
QUEUE_DB_number
+28.0
QUEUE_DB_address 0
=30.0
Acknowledgment data in the TRACE command
The user data contained in the acknowledgment of the TRACE command are
written to the address parameterized in the command.
4-26
Starting
Commentary
Value
DW#16#0
MDS number, only MOBY U with multitag
'T'
MDS command: T = Trace (absolute read)
B#16#0
Not used
B#16#0
Not used
B#16#0
Not used
'xxxxxxxx'
Not used
L#1
Length in bytes of the data to be read
W#16#0
Physical start address of the data on the MDS
to be read
48
Data DB. The read data are written to this DB.
0
Address of the beginning of the user data in
the data DB
48
Not used
Not used
FC 56