System Alarm Report - NEC ASPILA EX Feature Manual

Hide thumbs Also See for ASPILA EX:
Table of Contents

Advertisement

90-11 : System Alarm Report

Level:
IN
Description
Input Data
Item No.
Conditions
Aspila EX Software Manual
Program 90 : Maintenance Program
Available.
Use Program 90-11 : System Alarm Report to define the details of the system alarm report.
01
System Alarm Display Telephone
Assign the display keyset port that should
receive system alarms.
02
Report Method
03
Destination for Report
Define the Remote Service Center telephone
number. This is the number the system dials
for Automatic Fault Reporting. The number
can be up to 24 digits long, using the charac-
ters 0-9, # and *.
04
Used a Trunk Group for Report
Define the trunk group used when placing
calls to the Service Center for Automatic
Fault Reporting.
05
Reported Customer ID
Define the site identification data sent to the
Service Center when automatically report-
ing a fault. The data can consist of alphanu-
meric characters up to 16 digits long.
06
SMTP Host Name
07
SMTP Host Port Number
08
To Address
09
Reply Address
10
From Address
11
DNS Primary Address
12
DNS Secondary Address
13
Customer Name
None
90-11 : System Alarm Report
Aspila EX
Item
Input Data
Extension Number
(Up to 8 digits)
0- No report
1- Auto-Call to outside
Telephone Number
(Up to 24 digits)
0-100
Customer ID
(Up to 16 digits)
Up to 255 Characters
0-65535
Up to 255 Characters
Up to 255 Characters
Up to 255 Characters
0.0.0.0-255.255.255.255
0.0.0.0-255.255.255.255
Up to 255 Characteers
Programming
Default
No setting
0
No setting
0
No setting
No setting
25
No setting
No setting
No setting
0.0.0.0
0.0.0.0
No setting
1041