Program 34 : Tie Line Setup; E&M Tie Line Basic Setup - NEC ASPILA EX Feature Manual

Hide thumbs Also See for ASPILA EX:
Table of Contents

Advertisement

Program 34 : Tie Line Setup

34-01 : E&M Tie Line Basic Setup
Program 34 : Tie Line Setup
34-01 : E&M Tie Line Basic Setup
Level:
IN
Description
Input Data
Trunk port number
Item
Item
No.
01
DID/E&M Start Signaling
02
DID/E&M Incoming Sig-
naling Type
03
E&M Dial-In Mode
04
E&M Line Dial tone
Conditions
Feature Cross Reference
812
Programming
Available.
Use Program 34-01 : E&M Tie Line Basic Setup to defines the basic settings for each E&M tie
line.
Input Data
nd
0- 2
dial tone
1- Wink
2- Immediate
3- Delay
0- Dial Pulse
1- PB (DTMF)
0- Extension num-
ber specify
1- Use conver-
sion table
0- Disable
1- Enable
None
Tie Lines
Aspila EX
Default
Description
1
Set the start signaling mode for
DID and tie trunks. DID and tie
trunks can use either immediate
start or wink start signaling.
0
For DID and tie trunks, use this
option to set the trunk's signal-
ing type (Dial Pulse or DTMF)
0
1
1-200
Related
Program
22-02
10-09
22-11
Aspila EX Software Manual

Hide quick links:

Advertisement

Table of Contents
loading