Table 2-9 SAS/SATA drive indicators
Indicator
Drive fault indicator
Drive activity indicator

2.9.3 NVMe SSD Indicators

Figure 2-44
Figure 2-44 NVMe SSD indicators
Table 2-10 NVMe SSD indicators
Green Indicator
Off
Steady green
Blinking green (2
Hz)
Off
Off
Steady green or
off
Issue 04 (2018-09-04)
State Description
l Steady yellow: The drive is not detected, the drive is faulty,
or the RAID array status of the drive is abnormal.
l Blinking yellow: The server is locating the drive or
rebuilding RAID.
l Off: The drive is operating normally.
NOTE
If the fault indicator is steady yellow, use the OS CLI to check the
RAID status to determine whether the RAID array status is abnormal
or whether the drive is faulty. For details about command description,
see the
l Steady green: The drive is inactive.
l Blinking green: Data is being read from the drive, written to
the drive, or synchronized between drives.
l Off: The drive is not detected or is faulty.
shows the NVMe SSD indicators.
Yellow
Indicator
Off
Off
Off
Blinking yellow
(2 Hz)
Blinking yellow
(0.5 Hz)
Steady yellow
Copyright © Huawei Technologies Co., Ltd.
Huawei V5 Server RAID Controller Card User
State Description
The NVMe SSD cannot be detected.
The NVMe SSD is detected and working
properly.
Data is being read from or written to the NVMe
SSD.
The NVMe SSD is being located or hot-swapped.
The NVMe SSD completes the hot removal
process and is removable.
The NVMe SSD is faulty.