Parameter List
Parameter list (by parameter number)
Pr.
Pr.
group
First free thermal reduction
600
H001
frequency 1
601
H002
First free thermal reduction ratio 1
First free thermal reduction
602
H003
frequency 2
603
H004
First free thermal reduction ratio 2
First free thermal reduction
604
H005
frequency 3
Power failure stop external signal
606
T722
─
input selection
─
607
H006
Motor permissible load level
Second motor permissible load
─
608
H016
level
PID set point/deviation input
609
A624
selection
610
A625
PID measured value input selection
611
F003
─
Acceleration time at a restart
Reverse rotation excitation current
617
G080
─
low-speed scaling factor
Cumulative pulse clear signal
635
M610
selection
Cumulative pulse division scaling
636
M611
factor
Control terminal option-Cumulative
637
M612
pulse division scaling factor
638
M613
Cumulative pulse storage
639
A108
Brake opening current selection
Brake operation frequency
640
A109
selection
Second brake sequence operation
641
A130
selection
642
A120
Second brake opening frequency
643
A121
Second brake opening current
Second brake opening current
644
A122
detection time
Second brake operation time at
645
A123
start
646
A124
Second brake operation frequency
Second brake operation time at
647
A125
stop
Second deceleration detection
648
A126
function selection
Second brake opening current
650
A128
selection
Second brake operation frequency
651
A129
selection
653
G410
Speed smoothing control
654
G411
Speed smoothing cutoff frequency
655
M530
Analog remote output selection
656
M531
Analog remote output 1
657
M532
Analog remote output 2
658
M533
Analog remote output 3
659
M534
Analog remote output 4
110
PARAMETERS
Name
Setting range
0 to 590 Hz, 9999
1 to 100%
0 to 590 Hz, 9999
1 to 100%
0 to 590 Hz, 9999
0, 1
110 to 250%
110 to 250%, 9999
1 to 5
1 to 5
0 to 3600 s, 9999
0 to 300%, 9999
0 to 3
1 to 16384
1 to 16384
0 to 3
0, 1
0, 1
0, 7, 8, 9999
0 to 30 Hz
0 to 400%
0 to 2 s
0 to 5 s
0 to 30 Hz
0 to 5 s
0, 1
0, 1
0, 1
0 to 200%
0 to 120 Hz
0, 1, 10, 11
800 to 1200%
800 to 1200%
800 to 1200%
800 to 1200%
Minimum
setting
Initial value
increments
0.01 Hz
9999
1%
100%
0.01 Hz
9999
1%
100%
0.01 Hz
9999
1
1
1%
150%
1%
9999
1
2
1
3
0.1 s
9999
0.1%
9999
1
0
1
1
1
1
1
0
1
0
1
0
1
0
0.01 Hz
3 Hz
0.1%
130%
0.1 s
0.3 s
0.1 s
0.3 s
0.01 Hz
6 Hz
0.1 s
0.3 s
1
0
1
0
1
0
0.1%
0%
0.01 Hz
20 Hz
1
0
0.1%
1000%
0.1%
1000%
0.1%
1000%
0.1%
1000%
Refer
to
page
317
317
317
317
317
526
317
317
488,
508
488,
508
515
595
227
227
227
227
457
457
457
457
457
457
457
457
457
457
457
457
624
624
386
386
386
386
386