(N) Operation via communication and its settings
• Real-time monitor
Refer to
page 347
for the register numbers and monitored items of the real time monitor.
• Parameters
Pr.
Register
41000 to
0 to 999
41999
902
41902
42092
902
43902
125 (903)
41903
42093
903
43903
904
41904
42094
904
43904
126 (905)
41905
42095
905
43905
917
41917
42107
917
43917
918
41918
42108
918
43918
919
41919
42109
919
43919
920
41920
42110
920
43920
926
41926
42116
926
43926
927
41927
42117
927
43927
928
41928
42118
928
43928
929
41929
42119
929
43929
932
41932
580
PARAMETERS
Name
For details on parameter names, refer
to the parameter list
(page
96).
Terminal 2 frequency setting bias
(frequency)
Terminal 2 frequency setting bias
(analog value)
Terminal 2 frequency setting bias
(terminal analog value)
Terminal 2 frequency setting gain
(frequency)
Terminal 2 frequency setting gain
(analog value)
Terminal 2 frequency setting gain
(terminal analog value)
Terminal 4 frequency setting bias
(frequency)
Terminal 4 frequency setting bias
(analog value)
Terminal 4 frequency setting bias
(terminal analog value)
Terminal 4 frequency setting gain
(frequency)
Terminal 4 frequency setting gain
(analog value)
Terminal 4 frequency setting gain
(terminal analog value)
Terminal 1 bias frequency (speed)
Terminal 1 bias (speed)
Terminal 1 bias (speed)
(terminal analog value)
Terminal 1 gain frequency (speed)
Terminal 1 gain (speed)
Terminal 1 gain (speed)
(terminal analog value)
Terminal 1 bias command (torque)
Terminal 1 bias (torque)
Terminal 1 bias (torque)
(terminal analog value)
Terminal 1 gain command (torque)
Terminal 1 gain (torque)
Terminal 1 gain (torque)
(terminal analog value)
Terminal 6 bias frequency (speed)
Terminal 6 bias (speed)
Terminal 6 bias (speed)
(terminal analog value)
Terminal 6 gain frequency (speed)
Terminal 6 gain (speed)
Terminal 6 gain (speed)
(terminal analog value)
Terminal 6 bias command (torque)
Terminal 6 bias (torque)
Terminal 6 bias (torque)
(terminal analog value)
Terminal 6 gain command (torque)
Terminal 6 gain (torque)
Terminal 6 gain (torque)
(terminal analog value)
Terminal 4 bias command (torque)
Read/Write
Read/Write
The parameter number + 41000 is the register number.
Read/Write
Read/Write
Analog value (%) set to Pr.902
Analog value (%) of voltage (current) applied to
Read
terminal 2
Read/Write
Read/Write
Analog value (%) set to Pr.903
Analog value (%) of voltage (current) applied to
Read
terminal 2
Read/Write
Read/Write
Analog value (%) set to Pr.904
Analog value (%) of current (voltage) applied to
Read
terminal 4
Read/Write
Read/Write
Analog value (%) set to Pr.905
Analog value (%) of current (voltage) applied to
Read
terminal 4
Read/Write
Read/Write
Analog value (%) set to Pr.917
Read
Analog value (%) of voltage applied to terminal 1
Read/Write
Read/Write
Analog value (%) set to Pr.918
Read
Analog value (%) of voltage applied to terminal 1
Read/Write
Read/Write
Analog value (%) set to Pr.919
Read
Analog value (%) of voltage applied to terminal 1
Read/Write
Read/Write
Analog value (%) set to Pr.920
Read
Analog value (%) of voltage applied to terminal 1
Read/Write
Read/Write
Analog value (%) set to C31 (926)
Analog value (%) of voltage applied to terminal 6 of the
Read
FR-A8AZ
Read/Write
Read/Write
Analog value (%) set to C33 (927)
Analog value (%) of voltage applied to terminal 6 of the
Read
FR-A8AZ
Read/Write
Read/Write
Analog value (%) set to C35 (928)
Analog value (%) of voltage applied to terminal 6 of the
Read
FR-A8AZ
Read/Write
Read/Write
Analog value (%) set to C37 (929)
Analog value (%) of voltage applied to terminal 6 of the
Read
FR-A8AZ
Read/Write
Remarks