Parameter settings for a motor with encoder
2.9
Parameter settings for a motor with
encoder
Parameter for the encoder (Pr.359, Pr.369, Pr.851, Pr.852)
• Set the encoder specifications.
Pr.
Name
359
852
Encoder rotation
C141
C241
direction
369
851
Number of
C140
C240
encoder pulses
The above parameters can be set when a vector control compatible option is mounted.
• The following table shows parameters to be set according to the vector control compatible option to be used.
Item
FR-A8APA parameter
Encoder/Resolver
Pr.359
rotation direction
Number of detector
Pr.369
pulses
Parameter settings for the motor under vector control
• Values in
Motor name
Standard motor
(thermal characteristic: standard)
Constant-torque motor
(thermal characteristic: constant
torque)
Vector control dedicated motor
Other manufacturer's standard
motor
Other manufacturer's constant-
torque motor
PM motor
Offline auto tuning is required (Refer to
Set this parameter according to the motor.
Use the thermal protector input provided with the motor.
64
INSTALLATION AND WIRING
Initial
Setting
value
range
Set when using a motor for which forward
0
rotation (encoder) is clockwise (CW) viewed
from the shaft
100
1
Set when using a motor for which forward
1
rotation (encoder) is counterclockwise (CCW)
viewed from the shaft
101
Set the number of encoder pulses output.
1024
0 to 4096
Set the number of pulses before it is multiplied by 4.
FR-A8AP/FR-A8AL/
FR-A8APR parameter FR-A8APS parameter
― (fixed 1024 pulses)
indicate initial values.
Pr.9
Electronic
thermal O/L
relay
Rated motor
0
current
Rated motor
1
current
0
30
Rated motor
0(3)
current
Rated motor
1(13)
current
Refer to the instruction manual of the FR-A8APR.
page
426.)
CW
CCW
— (obtained via
communication from the
encoder)
Pr.71
Pr.80
Applied
Motor
motor
capacity
Motor
Number of
capacity
motor poles
Motor
4
capacity
Motor
4
capacity
Motor
Number of
capacity
motor poles
Motor
Number of
capacity
motor poles
Description
Set for the operation at 120 Hz or
less.
Set for the operation at a
frequency higher than 120 Hz.
Set for the operation at 120 Hz or
less.
Set for the operation at a
frequency higher than 120 Hz.
FR-A8TP parameter
Pr.852
Pr.851
Pr.81
Pr.359/Pr.852
Number of
Encoder
motor
rotation
poles
direction
1
1
1
Pr.369/Pr.851
Number of
encoder
pulses
1024
1024
2048