Mitsubishi Electric 800 Series Instruction Manual page 436

600v class specification inverter
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Tuning the second applied motor
• When one inverter switches the operation between two different motors, set the second motor in Pr.450 Second applied
motor. (Refer to
page
423.) In the initial setting, no second motor is applied.
• Turning ON the RT signal will enable the parameter settings for the second motor as shown below.
Function
Motor capacity
Number of motor poles
Motor excitation current
Rated motor voltage
Rated motor frequency
Motor constant (R1)
Motor constant (R2)
Motor constant (L1)/d-axis
inductance (Ld)
Motor constant (L2)/q-axis
inductance (Lq)
Motor constant (X)
Auto tuning setting/status
Frequency search gain
NOTE
• The RT signal is assigned to the terminal RT in the initial status. Set "3" in any of Pr.178 to Pr.189 (Input terminal function
selection) to assign the RT signal to another terminal.
• Changing the terminal assignment using Pr.178 to Pr.189 (Input terminal function selection) may affect the other
functions. Set parameters after confirming the function of each terminal.
Parameters referred to
???????
Pr.1 Maximum frequency
Pr.9 Electronic thermal O/L relay
Pr.31 to Pr.36 Frequency jump
Pr.71 Applied motor
page 423
Pr.156 Stall prevention operation selection
Pr.178 to Pr.189 (Input terminal function selection)
Pr.190 to Pr.196 (Output terminal function selection)
Pr.800 Control method selection
RT signal ON (second motor)
Pr.453
Pr.454
Pr.455
Pr.456
Pr.457
Pr.458
Pr.459
Pr.460
Pr.461
Pr.462
Pr.463
Pr.560
page 317
page 332
page 415
page 370
page 137
(C) Motor constant parameters
RT signal OFF (first motor)
Pr.80
Pr.81
Pr.82
Pr.83
Pr.84
Pr.90
Pr.91
Pr.92
Pr.93
Pr.94
Pr.96
Pr.298
435
PARAMETERS
5
GROUP
C

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents